Capacity-resistance flue gas humidity transmitter can be widely applied in the humidity and dew point measurement and analysis in CEMS desulfurization and denitrification devices and power plant, etc.
Capacity-resistance flue gas humidity transmitter uses the original imported sensor chip, which can effectively ensure the accuracy and service life of the instrument. The function of built-in temperature compensation could reduce the influence from temperature change on the measured accuracy of humidity.
1.The display modes of absolute humidity, relative humidity,high-temperature dew point and %Vol can be shifted freely;
2.OLED auto-glowing display makes the display visual and the operation easy and convenient;
3.The imported sensor chip could guarantee the accuracy and serving life of the transmitter;
4.The function of built-in temperature compensation could reduce the influence from temperature change on the measured accuracy of humidity.
Test principle | capacity-resistance principle |
Display mode | 128×64 matrix dot OLED |
Measurement range | high-temperature dew point: -20 ~ +100℃ absolute humidity: 0 ~ 400g/m³ absolute humidity: 0 ~ 40.0%Vol relative humidity: 0 ~ 100%RH (only one mode can be displayed, so please indicate the message when ordering) |
Accuracy | ≤±1.5%FS |
Resolution | high-temperature dew point :0.1℃, Relative humidity and absolute humidity:0.1% |
Repeatability | ≤±1% |
Response time | T90≤15S |
Analog output | 4-20mA.DC(non-isolated output, loaded resistance lower than 500 Ohm) 1 way programmable alarm output (Dry contact type, maximum load 220VAC/2A) |
Communication port | RS232(default)or RS485 |
Power supply | 12~32VDC /100mA |
Sample gas temperature | 0 ~ 170℃ |
Environment humidity | <80%RH |
Sampling mode | sample gas pass-in |
Sample gas composition | no flammable gas, no strongly corrosive gas, the dust amount less than 1mg/Nm3 |
Sampling port | Φ6 stainless steel cutting ferrule(316L) |
Appearance Size | Gauge: 62mm×150mm×105mm(H×W×D) |
Install size | 133mm×48mm(W×D) |
Serving life | >24 months(under normal use) |
Install mode | rear panel mount(gauge) |
Disclaimer: The product introduction content (including product images, product descriptions, technical parameters, etc.) of this site is for reference only. As the update may not be timely, there will be some differences between the content and the actual situation. Please contact our sales staff to confirm. The information provided on this site does not constitute any offer or promise, and the company will improve and modify any information on the website from time to time without prior notice.
Copyright © Zhengzhou CY Scientific Instrument Co., Ltd. All Rights Reserved Update cookies preferences
| Sitemap | Technical Support: