Home > Products > Gas analyzer
Capacity-resistance flue gas humidity transmitter

Capacity-resistance flue gas humidity transmitter

    Capacity-resistance flue gas humidity transmitter can be widely applied in the humidity and dew point measurement and analysis in CEMS desulfurization and denitrification devices and power plant, etc.

Capacity-resistance flue gas humidity transmitter uses the original imported sensor chip, which can effectively ensure the accuracy and service life of the instrument. The function of built-in temperature compensation could reduce the influence from temperature change on the measured accuracy of humidity. 

Capacity-resistance flue gas humidity transmitter main features:

1.The display modes of absolute humidity, relative humidity,high-temperature dew point and %Vol can be shifted freely;

2.OLED auto-glowing display makes the display visual and the operation easy and convenient;

3.The imported sensor chip could guarantee the accuracy and serving life of the transmitter;

4.The function of built-in temperature compensation could reduce the influence from temperature change on the measured accuracy of humidity.

Capacity-resistance flue gas humidity transmitter technical parameters:

Test principle

capacity-resistance principle

Display mode

128×64 matrix dot OLED 

Measurement range

high-temperature dew point: -20 ~ +100

absolute humidity: 0 ~ 400g/m³

absolute humidity: 0 ~ 40.0%Vol

relative humidity: 0 ~ 100%RH

(only one mode can be displayed, so please indicate the message when ordering)

Accuracy

≤±1.5%FS

Resolution

high-temperature dew point :0.1℃, Relative humidity and absolute humidity:0.1%

Repeatability

≤±1%

Response time

T90≤15S

Analog output

4-20mA.DC(non-isolated output, loaded resistance lower than 500 Ohm)

1 way programmable alarm output (Dry contact type, maximum load 220VAC/2A)

Communication port

RS232(default)or RS485

Power supply

12~32VDC /100mA

Sample gas temperature

0 ~ 170

Environment humidity

80%RH

Sampling mode

sample gas pass-in

Sample gas composition

no flammable gas, no strongly corrosive gas, the dust amount less than 1mg/Nm3

Sampling port

Φ6 stainless steel cutting ferrule(316L)

Appearance Size

Gauge: 62mm×150mm×105mm(H×W×D)

Install size

133mm×48mm(W×D)

Serving life

24 months(under normal use)

Install mode

 rear panel mount(gauge)

Disclaimer: The product introduction content (including product images, product descriptions, technical parameters, etc.) of this site is for reference only. As the update may not be timely, there will be some differences between the content and the actual situation. Please contact our sales staff to confirm. The information provided on this site does not constitute any offer or promise, and the company will improve and modify any information on the website from time to time without prior notice.

Contact Us
  • E-mail: cysi@cysi.wang
  • Tel: +86 371 5519 9322
  • Fax: +86 371 8603 6875
  • Add: No. 820, 8th Floor, 1st Unit, 9th Block, Cuizhu Street, High-Tech Zone, Zhengzhou, Henan, China




Follow Us

Copyright © Zhengzhou CY Scientific Instrument Co., Ltd. All Rights Reserved    Update cookies preferences

| Sitemap |       Technical Support: